Roof Panel Installation

Precision Panel Structural Insulated Roof Panels need to bear on a ridge beam, purlins, rafters and / or walls. Most commonly, a Precision Panel Roof Panel will span freely from a ridge beam to the side wall and terminate at the eave. The eave length can vary and the roof panel can cantilever 4' from the wall.

Using a boom truck (for larger beams) the beam is lifted into place. The lumber wraps are sandwiched between the wall panel skins. Once the beam is in place, nail or screw through the OSB skins into the end of the beam as well.



The Precision Panel Structural insulated roof panel thickness for any project is determined by knowing the longest horizontal span (not the 'run length' of a panel) and the minimum design load requirement (snow load) for the area in which the panels will be installed. Precision Panel can help you determine the required thickness of your Precision Panel Structural Insulated Roof Panels.